header background-block header background-block header background-block header background-block

Find your product

NanoCellect® Biomedical, Inc.

VERLO Image-Guided Cell Sorter

Sort Cells You Can See With the Gentle Microfluidics You Know

The VERLO™ Image-Guided Cell Sorter is providing conventional flow cytometry and cell sorting along with the ability to perform imaging analysis to identify and sort cells based on morphology, subcellular localization and more.

filler image

VERLO Features

The VERLO™ Image-Guided Cell Sorter is providing conventional flow cytometry and cell sorting along with the ability to perform imaging analysis to identify and sort cells based on morphology, subcellular localization and more.

The VERLO™ instrument expands the capabilities of gentle benchtop microfluidic cell sorting. With two lasers and nine colors, plus 3 label-free parameters, it maintains simple workflows for either bulk sorting or single-cell dispensing into 96- or 384-well plates with an integrated cell dispensing and sample cooling.

Adding Image Analysis to Gentle Microfluidic Cell Sorting

  • Spatial Information
    Captures images of each cell. In addition to fluorescence intensity, the VERLO provides spatial information such as cell morphology and marker localization
  • Increased Precision Sorting
    Following the acquisition and processing of cell images, imaging features are incorporated into the gating strategy to define cell phenotypes
  • Enhanced Resolution
    Imaging of subcellular structures and analysis of spatial variations in brightfield, darkfield, and fluorescent images
  • Multivariate Datasets
    Combines high-throughput sampling with single-cell image acquisition and measures large number of features from cell images, providing more comprehensive data

VERLO™ Image Sorting Technology

12-Parameter Image-Guided Sorting

With 488 nm and 561 nm lasers to detect up to 9 fluorescent markers and 3 channels of label-free information, the VERLO Image-Guided Cell Sorter can identify key structures, such as golgi and nuclei, internalization, overall morphology, and nuanced texture features that can discriminate live-dead—as well as the physiology of the cells.

Once you have decided on which morphological features of the cells you want to sort, you can gate on image features such as Area vs Max Intensity, just like you would when sorting using FSC vs BSC. The image features are calculated in real-time, enabling you to begin sorting your samples without having to first analyze the whole sample and then run it through the instrument again.

filler image

Microfluidics

The VERLO™ Image-Guided Cell Sorter uses patented, microfluidic-based sorting with robust laser-excitation and sensitive PMT detectors to isolate mammalian cells, microbes, plant cells and more. A gentle and precise piezoelectric actuator directs cells into collection channels and allows analysis and sorting in a disposable format. This eliminates sample-to-sample contamination and biohazard exposure or cleanup. This technology allows the VERLO™ to sort up to 200 cells per second with high accuracy and effective recovery. Deposit 1 to 100 cells per well in a 96- or 384 well plate using a single-cell sorting cartridge and integrated Single-Cell Dispenser. CellVantage Software VERLO™ integrated platform uses patented, microfluidic-based sorting with robust laser-excitation and sensitivePMT detectors to isolate mammalian cells, microbes, plant cells and more. Agentle and precise piezoelectric actuator directs cells into collection channels and allows analysis and sorting in a disposable format. This eliminates sample-to-sample contamination and biohazard exposure or cleanup.

filler image
  • Unique to NanoCellect are our disposable cartridges that allow for bulk sorting or single-cell sorting. 
  • The sorting cartridges use a piezoacoustic actuator that gently directs cells into collection channels; an embedded cell sorting verification system gives instant feedback of sorting accuracy. 
  • This technology allows the VERLO™ to sort up to 200 cells per second with high accuracy and effective recovery. 
  • Sort two selected cell populations with bulk sorting while the remainder of cells collects in a third channel. 
  • Deposit 1 to 100 cells per well in a 96- or 384 well plate using a single-cell sorting cartridge and integrated Single-Cell Dispenser.

Multimedia

filler image

News & Events

On-Demand Webinar

NanoCellect Webinar on

Unveiling VERLO: The Future of Image-Guided Cell Sorting

This presentation introduces the VERLO™ Image-Guided Cell Sorter from NanoCellect. VERLO integrates advanced image-guidance technology with cell sorting, enhancing precision and efficiency. The system captures images of individual cells, providing spatial information such as cell morphology and marker localization. Enhanced resolution imaging capabilities allow for the visualization and analysis of subcellular structures and spatial variations in brightfield, darkfield, and fluorescent images. VERLO’s gating strategy incorporates imaging features to define cell phenotypes, increasing the precision of cell sorting. The system combines low-pressure microfluidics with single-cell image acquisition to measure a multitude of features from cell images, generating comprehensive multivariate datasets.

Applications of VERLO include:

  • Label-free cell structure analysis
  • Investigation of cell-cell interactions
  • Study of nuclear translocation
  • Cell organelle staining.

This presentation will delve into the technological details and potential applications of the VERLO, allowing researchers to study cells in their physiologically relevant state in downstream processes.

Resources

Downloads

Supplier

NanoCellect Biomedical Inc.

Visit Suppliers Website

Request a demo or a quote

Measure mitochondrial respiration and glycolysis as well as ATP production rate of live cells.

Measure mitochondrial respiration, glycolysis, and ATP production in live cells in a 96-well format

Overview of Consumables for XF Analyzers

Simple, Automated, Charge-based DNA and RNA Extraction

LUNA-FX7™ Automated Fluorescence Cell Counter with unmatched cell counting accuracy

LUNA-III™ Automated Brightfield Cell Counter, designed to enhance your productivity and precision.

High multiplexing, high resolution in situ platform to combine single-cell and spatial genomics.

The best super-resolution microscopy experience, on your desktop.

NovoCyte Opteon Spectral Flow Cytometer Systems 3-5 Lasers and 73 detectors

The NovoCyte Penteon™ is a 5 laser benchtop flow cytometer with up to 30 colors

Pixel – Visualize live cell function at scale

Discover the World's First Two-Laser Image-guided Cell Sorter

Benchtop Microfluidic Cell Sorting with Two Lasers and up to Nine Colors

An incubator designed specifically for the cultivation of primary human cells

Seahorse XFe24 Analyzers measure OCR and ECAR of live cells in a 24-well plate format.

Automated high content image acquisition and analysis for drug discovery and cell biology

Multicolor fluorescence imaging to data analysis in one device

IsoLight – Automated Cellular Proteomics Hub

IsoLight and IsoSpark – Single-Cell Functional Proteomics Hub

The LUNA-FL™ can count in both brightfield and fluorescence mode

The LUNA-II™ automated cell counter gives you the ultimate brightfield cell counting experience.

The MARS® System is the “one-stop” modular solution for complete cell isolation from complex samples

The NovoCyte Quanteon™ is a 4 laser benchtop flow cytometer with up to 25 colors

The QUANTOM Tx Microbial Cell Counter automatically identifies and counts individual bacterial cells

Single Cells or Nuclei from Solid Tissues in Minutes

Tapestri® Platform: Untangle the complexity of cancer with true multi-omics.

Sterile, easy-to-use solutions for high cell integrity of single cell dispensing

Tissue Clearing System for electrophoretic tissue clearing

Optimized Microplate Solutions for Research & Drug Discovery

DeepLabel™ Antibody Staining Kit for Cleared Tissues

IsoPlexis Solutions and Kits

Autofocusing cell counting and declustering algorithm that counts individual yeast cells

Automated Fluorescence Cell Counter for Stem Cells & SVF

The NovoCyte Advanteon provides the flexibility of 1, 2, or 3 laser options.

Accurate & efficient single-cell detection of SNVs, indels, CNVs and LOH across targeted gene panels

Measure functional metabolism in 3 dimensions from in vitro spheroids

NovoCyte Consumables and Accessories for your Flow Cytometry needs.

Kits and reagents for real-time fluorescence plate reader-based live cell metabolism assays

Sterile, easy-to-use solutions for high cell integrity of single cell dispensing

The best value benchtop flow cytometer with high flexibility, enhanced sensitivity and resolution.

Optimized solution for assessing mitochondrial function.

Provides real-time measurements of glycolysis

Measures human (Hu) T cell activation response within several minutes of stimulation

Formulated media based on common culture media DMEM or RPMI, and optimized for use in XF assays.

Analytical method for measuring basal state mitochondrial fuel oxidation in live cells

Identification of drug-induced mitochondrial toxicity

Provides validated reagents to measure long chain fatty acid oxidation (FAO)

For in vitro studies of long chain fatty acid oxidation by intact cells.

Permeabilizes intact cells in culture, selectively targeting the cellular plasma membrane.

Seahorse XF Real-Time ATP Rate Assay

A suite of optimized solutions for rapidly measuring cellular substrate oxidation

Robust & accurate measurements of both glycolytic and mitochondrial activities in T cell populations

An Error occurred please try again later.
Please fill in all mandatory fields.

* All mandatory fields must be completed.

Thank you for contacting us!

{{ successMessage }}